Manual
11/06 MN03407001Z-EN
replaces 11/06 AWB1251-1590GB
Connection System SmartWire
SWIRE-GW-DP
   All brand and product names are trademarks or registered trademarks
of the owner concerned.
Emergency On Call Service
Please call your local representative:
http://www.eaton.com/moeller/aftersales
or
Hotline of the After Sales Service:
+49 (0) 180 5 223822 (de, en)
AfterSalesEGBonn@eaton.com
Original Operating Instructions
The German-language edition of this document is the original operating
manual.
Translation of the original operating manual
All editions of this document other than those in German language are
translations of the original German manual.
1
st
published 2006, edition date 11/06
© 2006 by Eaton Industries GmbH, 53105 Bonn
Production: Heidrun Riege
Translation: David Long
All rights reserved, including those of the translation.
No part of this manual may be reproduced in any form (printed, photo-
copy, microfilm or any other process) or processed, duplicated or distri-
buted by means of electronic systems without written permission of
Eaton Industries GmbH, Bonn.
Subject to alteration without notice.
Danger!
Dangerous electrical voltage!
Before commencing the installation
• Disconnect the power supply of the device.
Ensure that devices cannot be accidentally
restarted.
Verify isolation from the supply.
Earth and short circuit.
Cover or enclose neighbouring units that
are live.
Follow the engineering instructions
(IL/AWA) of the device concerned.
Only suitably qualified personnel in
accordance with EN 50110-1/-2
(VDE 0105 Part 100) may work on this
device/system.
Before installation and before touching
the device ensure that you are free of
electrostatic charge.
The functional earth (FE) must be
connected to the protective earth (PE) or
to the potential equalisation. The system
installer is responsible for implementing
this connection.
Connecting cables and signal lines should
be installed so that inductive or capacitive
interference does not impair the
automation functions.
Install automation devices and related
operating elements in such a way that they
are well protected against unintentional
operation.
Suitable safety hardware and software
measures should be implemented for the
I/O interface so that a line or wire breakage
on the signal side does not result in
undefined states in the automation
devices.
Ensure a reliable electrical isolation of the
low voltage for the 24 volt supply. Only
use power supply units complying with
IEC 60364-4-41 (VDE 0100 Part 410) or
HD 384.4.41 S2.
Deviations of the mains voltage from the
rated value must not exceed the tolerance
limits given in the specifications, otherwise
this may cause malfunction and dangerous
operation.
Emergency stop devices complying with
IEC/EN 60204-1 must be effective in all
operating modes of the automation
devices. Unlatching the emergency-stop
devices must not cause restart.
Devices that are designed for mounting in
housings or control cabinets must only be
operated and controlled after they have
been installed with the housing closed.
Desktop or portable units must only be
operated and controlled in enclosed
housings.
I
 Measures should be taken to ensure the
proper restart of programs interrupted
after a voltage dip or failure. This should
not cause dangerous operating states even
for a short time. If necessary, emergency-
stop devices should be implemented.
Wherever faults in the automation system
may cause damage to persons or property,
external measures must be implemented to
ensure a safe operating state in the event
of a fault or malfunction (for example, by
means of separate limit switches,
mechanical interlocks etc.).
II
11/06 MN03407001Z-EN
Contents
About this manual
3
Intended users
3
Additional device manuals
3
Reading convention
4
1 About the PROFIBUS-DP gateway
SWIRE-GW-DP
5
System overview
5
Design of the SWIRE-GW-DP
6
Description of function
6
2 Installation 9
Set PROFIBUS-DP station address 9
Connect SmartWire connection cable 10
Connect supply voltages 11
Connect PROFIBUS-DP 12
Connection assignment PROFIBUS-DP 13
Terminating resistors 14
EMC-conformant wiring of the network 14
Potential separations 15
Data transfer rates – automatic baud rate detection 16
Maximum distances/bus cable lengths
16
3 Commissioning
19
Initial switch on
19
Meaning of the status LEDs
20
–Ready-LED
20
– U-Aux-LED
20
– SmartWire LED
21
– PROFIBUS LED
21
1